2017 Newest Hospital/Clinical Multi-Function Infusion Pump (MSLIS23)

<div class="bsc-item"> Model NO.: MSLIS23
Built-in Battery Work Time: More Than 2 Hours
Weight: 3.8kg
Trademark: MSL
Transport Package: Standard Export Package
Specification: 185*115*196cm
Origin: Guangdong China
HS Code: 9018909000
2017 Newest hospital/clinical Multi-function Infusion Pump(MSLIS23)
 
Product brief introduction:

The MSLIS23  infusion pump is the second generation product by our company. It has LCD display screen and micro computer controlled. The peristaltic pump is power source with multiple sensors to 
monitor the infusion pump and has variety of alarm functions. It's easy to operate and meets all the 
demand of various cases of transfusion, like single infusion, infusion two liquids at the same time or 
infusion for two people. Using infusion apparatus with the infusion pump, it can control the liquid flow to 
the patient.


 functions:
- Automatic infusion: According to the doctor's advice, set the infusion volume and speed. The linear 
peristaltic pump which is microcomputer controlled will manage infusion pump to make automatic 
infusion according to the setting infusion speed.

- KVO status: After finishing the the total volume of infusion, the pump will switch to KVO status 
automatically. (keep vein open status). 

- Audible and visual alarm: Five kinds of alarms including Occlusion alarm, Bubble alarm, Door Open 
alarm, Infusion Finished alarm and Under voltage alarm. When infusion failed, audible and visual alarm 
will occur and remind the operators to dispose in time.

- Apply to variety liquids: It can be used to infuse colorless transparent liquid and high nutrient solutions 
and color opaque liquid.

- Apply to infusion apparatus
   Ordinary infusion apparatus: Normal PVC titration transparent or lucifuge infusion apparatus (pipe 
diameter is about 3.5mm) can be used. Please make sure the pipe diameter and pipe wall of infusion
 apparatus must have a certain elasticity coefficient. New infusion apparatus should take calibration of 
the infusion precision before the first use.


Note: Other specifications of the infusion apparatus may not be able to maintain accuracy (Even if the precision is being calibrated)
   Specialized infusion apparatus: Specialized infusion apparatus has high elastic silicone tube. Please contact our company for purchasing. 
   Warning: The pump may be unable to maintain accuracy if use infusion apparatus which is not recommended.  


-   AC/DC alternative: Built-in NI-MH rechargeable battery makes sure the device still can be used 
when the sudden power off. The machine automatically charges itself when the battery volume is low and stop when it's fully charged, and the indication light switches off. Please make sure it's fully charged 
around 7hours or it will shorten the lifespan of battery. Low voltage alarm will occur and indication light 
will flash when the battery mostly runs out in order to remind the operators to dispose in time.

- Quick exhaust: Press the quick exhaust button twice and enter into quick exhaust status. The stop 
status is quick exhaust, and the exhausted liquid will not be counted into cumulative infusion rate. Start 
state is quick transfuse, discharged liquid will be counted into cumulative infusion rate. Loosen the 
button, the quick exhaust state will be stopped.

- Infusion rate: It has Drop/min and ml/h two setting modes for users to choose.
Note: Drop/min and ml/h is conversed from 20 Drops/ml, which is different from the actual drops.

- Call interface: Reserve call interface to provide the centralized monitoring function for  nurse station. 

 
Technical parameters: 
-  Infusion flow rate
Specialized infusion apparatus: 0.1ml/h-1200ml/h
       Ordinary infusion apparatus: 0.1ml/h-600ml/h; 
Remarks: with 0.1-30ml/h (0.1ml/h/step); over 30ml/h(1ml/h/step).
 
- Infusion accuracy error
   Specialized infusion apparatus:±5%(medium speed, 23ºC, humidity: 60%);
   Ordinary infusion apparatus:±10%(medium speed, 23ºC, humidity: 60%).
 
  
 Total infusion volume preset: 0.1-9999ml. 
   Remarks: with 0.1-30ml (0.1ml/step); 
            over 30ml (1ml/step).

 
Occlusion sensitivity  It has three adjustable levels of occlusion pressure as high, medium and low.
Low speed (1ml/h)  250~500 seconds;
Medium speed (120ml/h)  7~14 seconds;
High speed(600ml/h)  0.2~1 seconds.
 
Above data is measured at the status of 25ºC ambient temperature, ordinary pressure, use ordinary PVC(∮3)infusion apparatus and high sensitivity.
- KV0:1-2ml/h
- Power supply:
   A C:220V±22V    50Hz±1Hz
   D C: 12V (built-in battery).
-Fuse: F0.75AL(socket back), T1A (switching power supply L.N).
- Power consumption: 30VA.
-    Built-in battery work time:  
Under the sufficient battery, medium speed flow rate, the battery can continuous work about 2 hours after power is switched off. Run time is related to flow rate. Within the battery normal life, the run time should not be less than 2 hours. The battery could charge and discharge about 400 times. 

 
 
-Environmental temperature:+5ºC-+40ºC; 
Relative humidity: 20%-90%;
-Product dimension and weight:185×115×196(mm), 3.8kg. 

 
- security classification:
The equipment is conform to IEC60601-1-2 standard and can resist a certain electromagnetic interference,
which is no electromagnetic interference to other devices. However, please keep the infusion pump away from strong
electromagnetic equipment, for example: radio knife, MRI. 

 

Habio Brewing Industry Enzyme

China Food Aplication manufacturers, our Food Application, Food Application Online, Food Application Form are good in quality and competitive in price.

JFHDFHD , http://www.nbcatalase.com