What are the precautions for using the centrifuge?

1. When the centrifuge is in the pre-cooling state, the centrifuge cover must be closed. After the centrifuge is finished, the rotor should be placed on the test bench and the residual water in the chamber should be dried. The centrifuge cover is open.

2. When the rotor is pre-cooled, the rotor cover can be placed on the platform of the centrifuge, or placed on the test bench. Do not screw it on the rotor!

3. After the screw cap is tightened, be sure to touch the gap between the rotor and the cover with your fingers. If there is a gap, unscrew and retighten until the gap is confirmed before the centrifuge can be started.

4. During the centrifugation process, the operator must not leave the centrifuge room. If an abnormal situation occurs, the operator cannot turn off the power supply.) Press STOP. Fill in the centrifuge usage record before pre-cooling.

5. Do not use fake centrifuge tubes, and do not use aging, deformed, cracked centrifuge tubes.

6, after the holidays and evenings, after a routine safety check using a centrifuge, you can leave.

7. In the event of machine failure during the use of the instrument, the technician should be in time with the damage of the component.

8. The centrifuge must not be moved while the centrifuge is running.

9. The ground of the centrifuge should be solid and flat. The two leveling screws are adjusted to make the centrifuge contact with the ground and evenly stressed to avoid vibration.

10. Centrifugal tube should be weighed and balanced. If the difference is too large, large vibration will occur. At this time, stop the inspection and make the liquid meet the requirements. The centrifuge tube must be placed evenly symmetrically.

11. If there is a rupture of the centrifuge tube during operation, it will cause a large vibration and should be stopped immediately.

12. The time interval between restarts after each shutdown should not be less than 5 minutes, so as to avoid damage caused by compressor stall.

13. After each centrifugation, the rotor must be taken out. Otherwise, it will be placed on the shaft for a long time. It may rust and the rotor will not be taken out, which will cause the centrifuge to be scrapped.

14. The service life of the rotor is three years. The rotor should be replaced after the expiration.

15. All rotors cannot be used above their high speed.

Face Mask

We are a professional Mask Making Machine manufacturer with more than 5 years. Our masks are all come out from our machines. We have Disposable mask, surgical face mask, medical mask, KN95 mask and etc. To provide customers high quality products and high quality service is always our aim of work. We can be your reliable business partner!