ECG Machine

Features
7 inch high resolution color touch screen
12-lead simultaneous acquisition and display
ECG Automatic measurement and interpretation function
Complete digital filters , resisting baseline drift , AC and EMG interference
Compact and lightweight design
Support USB flash disk and micro SD card to extend memory
Software upgrade via USB / SD card
Built-in rechargeable Li-ion battery
Standard Configuration
Main machine: 1 PC
Patient cable: 1 PC
Limb electrode: 1set (4pcs)
Chest electrode: 1set (6pcs)
Power cable: 1 PC
20mm * 20M recording paper: 1 PC
Paper axis: 1 PC
Power cord: 1 PC

SE-12B Digital Three Channel Color Touch Screen ECG Machine(electrocardiograph)

Features
- The system is designed with a high-resolution thermal printer featuring 8dot/mm
vertical resolution and 40dot/mm horizontal resolution(at 25mm/s) speed and filter as
well as related marks.

- Simultaneously 12 lead signal acquisitions.
- Digital filter to prevent baseline drift and automatic positioning of the baseline provide
accurate ECG trace.

- Able to detect and alarm on electrode disconnection.
- LED indicator and LCD display show operation status of the unit.
- Isolated input circuit guarantees safety standard in compliance to Class I type CF.
- AC/Rechargeable battery supports continuous operation when AC power supply is not
available. For the battery operation, the system is equipped with a battery charger and
a system for battery capacity management and protection.

- Compact size.

Specifications
Lead: Standard or Cabrera 12 leads,Simultaneously 12 leads acquisition
Sampling rate: 1000Hz(1ms)
Frequency Response: 0.05 ~ 150Hz
Time Constant:
≥3.2s
CMRR:
>100dB
Input Circuit:
<0.1 µA
Noise Level: ≤ 8 µVp∽p
Polarization Voltage:
±500mV
Sensitivity valve: 20
µV
Calibration Voltage: 1mV
±0%
Filter: AC: 50Hz-20dB(or 60Hz); EMG
filter:25-35-45Hz-3dB;
Drift filter: 0.5Hz -3dB
Sensitivity: 1.25, 2.5, 5, 10, 20mm/mV
±2%,40 when format setted at 6ch or 3+3ch
Paper Speed: 5, 6.25, 10, 12.5, 25, 50mm/s ±3%
Recording MODE: Thermal array printer 8 dot/mm(Vertical) 40 dot/mm(Horizontal, 25mm/s)

Paper Size: 210mm20m or 216mm20m, thermal roll paper