Judging and Handling of Abnormal Function of Hongda New Intelligent Salt Spray Test Chamber |
|
Clicks:9 Release time:2010-8-10 |
|
shape    condition | original    because | At    Rational | The laboratory cannot rise to the set temperature | 01. Laboratory temperature controller temperature setting Too low 02. Laboratory safety switch has been set low 03. Heating system failure 04. Electromagnetic relay failure 05. Controller failure | 01. Set the temperature controller to the required temperature 02. Set the safety switch to the location Temperature required 03.Notify the company 04. Notify the company 05.Notify the company | Saturated barrel temperature cannot rise to the set temperature | 01. Saturated barrel temperature controller is too low  02. Saturated barrel safety switch set low 03. Heating system failure 04. Electromagnetic relay failure 05. Controller failure | 01. Set the temperature controller to the desired temperature 02. Set the safety switch to the location Temperature required 03.Notify the company 04. Notify the company 05.Notify the company | Insufficient amount of spray | 01. The spray regulator is placed too low 02. The glass filter in the preheating tank is blocked 03. Pressure setting is too low | 01. Increase the spray regulator 02. Clean the glass filter 03. Adjust the pressure regulator to 1kg / cm 2 of pressure, a compressor superscript pressure regulating valve is adjusted to 0.2 ~ 0.3Mpa / cm 2 of | When not spraying: air tube means with the method of the nozzle of the suction tube (- suction pipe type tube, L-type air tube)   | 01. The air compressor is not running 02. The main switch of the air compressor outlet is not Have opened 03. Solenoid valve failure 04. Pressure gauge failure or pressure is too low 05. Electromagnetic contactor failure 06. Nozzle blockage | 01. Turn on the air compressor button 02. Turn on the air compressor main switch  03.Notify the company 04. Notify the company 05.Notify the company 06. Remove the nozzle and clean it (please disassemble it carefully) |
shape     condition | original    because | At    Rational | When the amount of spray is too high | 01. The spray regulator is placed too high 02. Glass nozzle is used for a long time, spray The mouth is too large | 01. Spray regulator down 02. Replace the new glass nozzle | There is a normal spray and the air compressor is not running   | Air compressor itself has self-protection function | Use as usual | Cannot run after turning on the power | When the water level in the heating tank is too low, the power supply will be cut off. | When the water level in the heating tank is too low, the power supply will be cut off.  | Machine spray does not count | 01. The temperature has not risen  02. Set the time and spray time for the setting   Set the same | 01. Wait for the temperature to rise to -2 °C Start  Timing 02. Spray time and set time setting  Consistent | The time I have done is still retained | Not cleared | Press and hold "work" for 5 seconds to clear the time | Touch screen click no response | Lock interface | Press and hold simultaneously        5 seconds to unlock |
Beijing Hongda Tianmao Testing Equipment Co., Ltd. Technical Services: Click on the Internet: |
Tiamulin Fumarate Premix
Tiamulin Fumarate,Tiamulin Swine,Tiamulin Chicken,Tiamulin For Animal Use
Shandong Shengli Bioengineering Co., Ltd , https://www.shenglipharm.com