TOPSKY medical mobile cart medical electric care car CAN01

TOPSKY single-screen laptop computer stand medical mobile cart medical electric care car CAN01, suitable for 9.7-17.3-inch TV, the maximum load capacity is 5kg. Applicable to medical institutions, hospital departments, medical work stations and other occasions.

TOPSKY医疗移动推车电动护理车CAN01促

Pictured: TOPSKY single-screen laptop computer stand medical mobile cart medical electric care car CAN01

TOPSKY single-screen laptop integrated machine support medical mobile cart medical electric care car CAN01 can be used with open holes on both sides of the bottom of the inner groove. The table top can be opened, the table space is 482*261mm, the non-slip edge treatment, the surface antibacterial coating. The console is equipped with an LED display switch, button power and power and night light and sound settings for easy access.

TOPSKY医疗移动推车电动护理车CAN01促

Pictured: TOPSKY single-screen laptop computer stand medical mobile cart medical electric care car CAN01

Vtm Sampling Tube With Swab

[Sample requirements]
The collected nasopharyngeal swab samples should be transported at 2°C to 8°C and sent for inspection immediately, and the sample delivery and storage time should not exceed 48 hours.

[Testing method]
1. Before sampling, mark the relevant sample information on the label of the sampling tube.
2. According to different sampling requirements, use a sampling swab to sample in the nasopharynx.
3. The specific sampling methods are as follows:
a) Nasal swab: Gently insert the swab head into the nasal palate, stay for a while and then slowly turn to exit. Wipe the other nostril with another swab, immerse the swab head in the sampling solution, and discard the tail.

b) Pharyngeal swab: Wipe bilateral pharyngeal tonsils and posterior pharyngeal wall with a swab, also immerse the swab head in the sampling solution, and discard the tail.

4. Quickly put the swab into the sampling tube.
5. Break the part of the sampling swab higher than the sampling tube, and tighten the tube cover.
6. Freshly collected clinical specimens should be transported to the laboratory within 48 hours at 2°C to 8°C.

[Explanation of test results]
After the sample is collected, the sampling solution turns slightly yellow, which will not affect the nucleic acid test result.

[Limitations of the test method]
1. For samples that are seriously contaminated due to improper storage after collection, the final test results will be affected.
2. If the sample is not stored at the specified temperature, the final test result will be affected.


Vtm Sampling Tube With Swab,Disposable Collection Tube Of Virus Samples,Hi Media Vtm Kit,Amylase Sample Collection Tube

Jilin Sinoscience Technology Co. LTD , https://www.jlgkscience.com

Posted on