Characteristics and application of fiber optic pipetting probe

Characteristics and application of fiber optic pipetting probe
DipTipTM is a small transmission/absorbance probe for microliter spectrophotometers and is the world's smallest fiber optic pipetting probe for UV and visible spectrophotometers.
The tip of the DipTip is only 1.5 mm in diameter, which is equivalent to the size of a 17G needle. It is not only 4-5 times smaller in diameter than other products on the market, but also has a price that is nearly 50% lower. The probe can be applied to all centrifuge tubes on the market and is very useful for measuring protein and DNA samples. This small pipetting probe can also be used for solution dilution. WPI designed this product along with WPI's fiber optic-based spectrophotometer or spectrometer module (TIDAS I) or CCD and light source for analysis of microliter samples.
An example of the use of DipTip is the use of TIDAS II to analyze calf serum (BSA) dissolved in phosphate buffer. The absorbance range and calibration curve are shown in the figure below. A 50-60 microliter sample was taken from a 0.1 ml centrifuge tube to measure its absorbance.


Diptip parameters
Diptip parameters
DIP-UV
DIP-NIR
DIP-UV-SR
Tip diameter
1.5 mm
1.5 mm
1.5 mm
Light path length
2, 5, 10mm
2, 5, 10mm
2, 5, 10mm
Wavelength range (nm)
230-1000
350-1000
200-1000
Required sample volume
20-50 μL
20-50 μL
20-50 μL
Tip immersion depth
7 mm
7 mm
7 mm
Total length ( with handle )
18 cm
18 cm
18 cm
Fiber length ( from connector to tip )
1.5 m
1.5 m
1.5 m
Fiber optic connector
SMA 905
SMA 905
SMA 905
Launch fiber (2) NA = 0.22
400 μm
400 μm
400 μm
Return fiber (1) NA = 0.22
400 μm
400 μm
400 μm
TIDAS I is WPI's high-end spectrometer module based on fiber sampling technology that uses a suitable source and sample cell to perform spectral detection at 195-730 nm at very low noise levels (0.8 milliabsorbance). TIDAS I outperforms conventional spectrophotometers and CCD-based spectrometers with high-precision fiber sampling.

Water Bath

Use maintenance

A: The amount of clean tap water into the studio Water Tank, place the container.

B: Power on.

C: Select constant temperature:

Set the temperature "setting - measurement" selector switch to "Settings", adjust the temperature control knob, digital display the required set temperature.

Set the temperature "setting - measurement" selector switch to "measurement", the figure shows the actual working temperature of the water tank (red indicator light, indicating the heater work).

D: work is completed, the temperature control knob at the minimum, cut off the power.

E: If the water bath pot is not used for a long time, the water in the studio water tank should be excluded, wipe with a soft cloth and dry.

F: Do not use the heater in the water bath without water

Model

Specs

Single hole

DZKW-D-1

Double holes

DZKW-D-2

One line four holes

DZKW-D-4

One line six holes

DZKW-D-6

Double line four holes

DZKW-S-4

Double line six holes

DZKW-S-6

Double line eight holes

DZKW-S-8

Rated power(W)

300

500

1000

1500

1000

1500

2000

Work voltage(V)

220V 50Hz

temperature Uniformity

≤±1℃

temperature fluctuation

≤±1℃

Temperature control range

TR+10~100℃

Control temperature sensitivity

≤±1℃

Indication Error

≤±2℃



laboratory water bath

laboratory water bath

laboratory water bath

Factory:


Laboratory Water Bath


Laboratory Water Bath

Laboratory Water Bath



Water Bath,Laboratory Water Bath,Shaking Water Bath,Lab Water Bath

Cangzhou Blue Beauty Lab Instrument Co., Ltd. , https://www.czlabinstrument.com

Posted on